581 research outputs found

    MD2 PER-PATIENT-PER-MONTH DRUG COSTS IN MEDICARE PART D PROTECTED CLASSES

    Get PDF

    Robot-aided assessment of wrist proprioception

    Get PDF
    Introduction: Impaired proprioception severely affects the control of gross and fine motor function. However, clinical assessment of proprioceptive deficits and its impact on motor function has been difficult to elucidate. Recent advances in haptic robotic interfaces designed for sensorimotor rehabilitation enabled the use of such devices for the assessment of proprioceptive function. Purpose: This study evaluated the feasibility of a wrist robot system to determine proprioceptive discrimination thresholds for two different DoFs of the wrist. Specifically, we sought to accomplish three aims: first, to establish data validity; second, to show that the system is sensitive to detect small differences in acuity; third, to establish test–retest reliability over repeated testing. Methodology: Eleven healthy adult subjects experienced two passive wrist movements and had to verbally indicate which movement had the larger amplitude. Based on a subject’s response data, a psychometric function was fitted and the wrist acuity threshold was established at the 75% correct response level. A subset of five subjects repeated the experimentation three times (T1, T2, and T3) to determine the test–retest reliability. Results: Mean threshold for wrist flexion was 2.15° ± 0.43° and 1.52° ± 0.36° for abduction. Encoder resolutions were 0.0075° (flexion–extension) and 0.0032° (abduction–adduction). Motor resolutions were 0.2°(flexion–extension) and 0.3° (abduction–adduction). Reliability coefficients were rT2-T1 = 0.986 and rT3-T2 = 0.971. Conclusion: We currently lack established norm data on the proprioceptive acuity of the wrist to establish direct validity. However, the magnitude of our reported thresholds is physiological, plausible, and well in line with available threshold data obtained at the elbow joint. Moreover, system has high resolution and is sensitive enough to detect small differences in acuity. Finally, the system produces reliable data over repeated testing

    A soft, synergy-based robotic glove for grasping assistance

    Get PDF
    This paper presents a soft, tendon-driven, robotic glove designed to augment grasp capability and provide rehabilitation assistance for postspinal cord injury patients. The basis of the design is an underactuation approach utilizing postural synergies of the hand to support a large variety of grasps with a single actuator. The glove is lightweight, easy to don, and generates sufficient hand closing force to assist with activities of daily living. Device efficiency was examined through a characterization of the power transmission elements, and output force production was observed to be linear in both cylindrical and pinch grasp configurations. We further show that, as a result of the synergy-inspired actuation strategy, the glove only slightly alters the distribution of forces across the fingers, compared to a natural, unassisted grasping pattern. Finally, a preliminary case study was conducted using a participant suffering from an incomplete spinal cord injury (C7). It was found that through the use of the glove, the participant was able to achieve a 50% performance improvement (from four to six blocks) in a standard Box and Block test

    An Application of IoT in a Drone Inspection Service for Environmental Control

    Get PDF
    This paper presents an exploratory activity with a drone inspection service for environmental control. The aim of the service is to provide technical support to decision-makers in environmental risk management. The proposed service uses IoT for the interaction between a mobile application, a Smart City platform, and an Unmanned Aircraft System (UAS). The mobile application allows the users to report risky situations, such as fire ignition, spills of pollutants in water, or illegal dumping; the user has only to specify the class of the event, while the geographical coordinates are automatically taken from device-integrated GPS. The message sent from the mobile application arrives to a Smart City platform, which shows all the received alerts on a 3D satellite map, to support decision-makers in choosing where a drone inspection is required. From the Smart City platform, the message is sent to the drone service operator; a CSV file defining the itinerary of the drone is automatically built and shown through the platform; the drone starts the mission providing a video, which is used by the decision-makers to understand whether the situation calls for immediate action. An experimental activity in an open field was carried out to validate the whole chain, from the alert to the drone mission, enriched by a Smart City platform to enable a decision-maker to better manage the situation

    ROBOT-MEDIATED AND CLINICAL SCALES EVALUATION AFTER UPPER LIMB BOTULINUM TOXIN TYPE A INJECTION IN CHILDREN WITH HEMIPLEGIA

    Get PDF
    Objective: The aim of this pilot study was to examine changes in different aspects of impairment, including spasticity in the upper limbs, of hemiplegic children following botulinum toxin type A intervention. Progress was assessed using standard clinical measurements and a robotic device. Design: Pre-post multiple baseline. Subjects: Six children with hemiplegia. Methods: Botulinium toxin type A injections were administered into the affected upper limb muscles. Outcomes were evaluated before and one month after the injection. Outcome assessments included: Melbourne Scale, Modified Ashworth Scale (MAS) and Passive Range of Motion. Furthermore, a robotic device was employed as an evaluation tool. Results: Patients treated with botulinum toxin type A had significantly greater reduction in spasticity (MAS, p < 0.01), which explains an improvement in upper limb function and quality movement measured with the Melbourne Scale (p < 0.01). These improvements are consistent with robot-based evaluation results that showed statistically significant changes (p < 0.01) following botulinum toxin type A injections. Conclusion: The upper limb performs a wide variety of movements. The multi-joint nature of the task during the robotmediated evaluation required active control of joint interaction forces. There was good correlation between clinical scales and robotic evaluation. Hence the robot-mediated assessment may be used as an additional tool to quantify the degree of motor improvement after botulinum toxin type A injections

    Design, Computational Modelling and Experimental Characterization of Bistable Hybrid Soft Actuators for a Controllable-Compliance Joint of an Exoskeleton Rehabilitation Robot

    Get PDF
    This paper presents the mechatronic design of a biorobotic joint with controllable compliance, for innovative applications of “assist-as-needed” robotic rehabilitation mediated by a wearable and soft exoskeleton. The soft actuation of robotic exoskeletons can provide some relevant advantages in terms of controllable compliance, adaptivity and intrinsic safety of the control performance of the robot during the interaction with the patient. Pneumatic Artificial Muscles (PAMs), which belong to the class of soft actuators, can be arranged in antagonistic configuration in order to exploit the variability of their mechanical compliance for the optimal adaptation of the robot performance during therapy. The coupling of an antagonistic configuration of PAMs with a regulation mechanism can achieve, under a customized control strategy, the optimal tuning of the mechanical compliance of the exoskeleton joint over full ranges of actuation pressure and joint rotation. This work presents a novel mechanism, for the optimal regulation of the compliance of the biorobotic joint, which is characterized by a soft and hybrid actuation exploiting the storage/release of the elastic energy by bistable Von Mises elastic trusses. The contribution from elastic Von Mises structure can improve both the mechanical response of the soft pneumatic bellows actuating the regulation mechanism and the intrinsic safety of the whole mechanism. A comprehensive set of design steps is presented here, including the optimization of the geometry of the pneumatic bellows, the fabrication process through 3D printing of the mechanism and some experimental tests devoted to the characterization of the hybrid soft actuation. The experimental tests replicated the main operating conditions of the regulation mechanism; the advantages arising from the bistable hybrid soft actuation were evaluated in terms of static and dynamic performance, e.g., pressure and force transition thresholds of the bistable mechanism, linearity and hysteresis of the actuator response

    Resonantly excited exciton dynamics in two-dimensional MoSe2 monolayers

    Get PDF
    We report on the exciton and trion density dynamics in a single layer of MoSe2, resonantly excited and probed using three-pulse four-wave mixing (FWM), at temperatures from 300 K to 77 K. A multiexponential third-order response function for amplitude and phase of the heterodyne-detected FWM signal including four decay processes is used to model the data. We provide a consistent interpretation within the intrinsic band structure, not requiring the inclusion of extrinsic effects. We find an exciton radiative lifetime in the subpicosecond range consistent to what has been recently reported by Jakubczyk et al. [Nano Lett. 16, 5333 (2016)]. After the dominating radiative decay, the remaining exciton density, which has been scattered from the initially excited direct spin-allowed radiative state into dark states of different nature by exciton-phonon scattering or disorder scattering, shows a slower dynamics, covering 10-ps to 10-ns time scales. This includes direct spin-allowed transitions with larger in-plane momentum, as well as indirect and spin-forbidden exciton states. We find that exciton-exciton annihilation is not relevant in the observed dynamics, in variance from previous finding under nonresonant excitation. The trion density at 77 K reveals a decay of the order of 1 ps, similar to what is observed for the exciton. After few tens of picoseconds, the trion dynamics resembles the one of the exciton, indicating that trion ionization occurs on this time scale

    Performance adaptive training control strategy for recovering wrist movements in stroke patients: a preliminary, feasibility study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the last two decades robot training in neuromotor rehabilitation was mainly focused on shoulder-elbow movements. Few devices were designed and clinically tested for training coordinated movements of the wrist, which are crucial for achieving even the basic level of motor competence that is necessary for carrying out ADLs (activities of daily life). Moreover, most systems of robot therapy use point-to-point reaching movements which tend to emphasize the pathological tendency of stroke patients to break down goal-directed movements into a number of jerky sub-movements. For this reason we designed a wrist robot with a range of motion comparable to that of normal subjects and implemented a self-adapting training protocol for tracking smoothly moving targets in order to facilitate the emergence of smoothness in the motor control patterns and maximize the recovery of the normal RoM (range of motion) of the different DoFs (degrees of Freedom).</p> <p>Methods</p> <p>The IIT-wrist robot is a 3 DoFs light exoskeleton device, with direct-drive of each DoF and a human-like range of motion for Flexion/Extension (FE), Abduction/Adduction (AA) and Pronation/Supination (PS). Subjects were asked to track a variable-frequency oscillating target using only one wrist DoF at time, in such a way to carry out a progressive splinting therapy. The RoM of each DoF was angularly scanned in a staircase-like fashion, from the "easier" to the "more difficult" angular position. An Adaptive Controller evaluated online performance parameters and modulated both the assistance and the difficulty of the task in order to facilitate smoother and more precise motor command patterns.</p> <p>Results</p> <p>Three stroke subjects volunteered to participate in a preliminary test session aimed at verify the acceptability of the device and the feasibility of the designed protocol. All of them were able to perform the required task. The wrist active RoM of motion was evaluated for each patient at the beginning and at the end of the test therapy session and the results suggest a positive trend.</p> <p>Conclusion</p> <p>The positive outcomes of the preliminary tests motivate the planning of a clinical trial and provide experimental evidence for defining appropriate inclusion/exclusion criteria.</p

    Effects of a neuromuscular controller on a powered ankle exoskeleton during human walking

    Get PDF
    Wearable devices to assist abnormal gaits require controllers that interact with the user in an intuitive and unobtrusive manner. To design such a controller, we investigated a bio-inspired walking controller for orthoses and prostheses. We present (i) a Simulink neuromuscular control library derived from a computational model of reflexive neuromuscular control of human gait with a central pattern generator (CPG) extension, (ii) an ankle reflex controller for the Achilles exoskeleton derived from the library, and (iii) the mechanics and energetics of healthy subjects walking with an actuated ankle orthosis using the proposed controller. As this controller was designed to mimic human reflex patterns during locomotion, we hypothesize that walking with this controller would lead to lower energetic costs, compared to walking with the added mass of the device only, and allow for walking at different speeds without explicit control. Preliminary results suggest that the neuromuscular controller does not disturb walking dynamics in both slow and normal walking cases and can also reduce the net metabolic cost compared to transparent mode of the device. Reductions in tibialis anterior and soleus activity were observed, suggesting the controller could be suitable, in future work, for augmenting or replacing normal walking functions. We also investigated the impedance patterns generated by the neuromuscular controller. The validity of the equivalent variable impedance controller, particularly in stance phase, can facilitate serving subject-specific features by linking impedance measurement and neuromuscular controller

    On the coupling between molecular diffusion and solvation shell exchange

    Get PDF
    The connection between diffusion and solvent exchanges between first and second solvation shells is studied by means of molecular dynamics simulations and analytic calculations, with detailed illustrations for water exchange for the Li+ and Na+ ions, and for liquid argon. First, two methods are proposed which allow, by means of simulation, to extract the quantitative speed-up in diffusion induced by the exchange events. Second, it is shown by simple kinematic considerations that the instantaneous velocity of the solute conditions to a considerable extent the character of the exchanges. Analytic formulas are derived which quantitatively estimate this effect, and which are of general applicability to molecular diffusion in any thermal fluid. Despite the simplicity of the kinematic considerations, they are shown to well describe many aspects of solvent exchange/diffusion coupling features for nontrivial systems
    • …
    corecore